Procedure - Solid Samples
Prepare the instrument as outlined in the operator's instruction manual.
Determine the instrument blank.
Login a minimum of 3 Blank replicates.
Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open. Place a 502-344 Nickel Basket into the loading head.
Note: samples using automation should be placed in the appropriate autoloader position before starting the
analysis sequence. Once the sequence has started, the automatic analysis will start and end automatically.
Procedure - Solid Samples
Instrument calibration/drift correction.
Add approximately 0.05 g of *** Graphite Powder to a *** Graphite Crucible.
Firmly place the crucible on the lower electrode tip or appropriate autoloader position.
Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and end automatically.
Repeat steps 3b through 3j a minimum of three times for each calibration/drift standard used.
Calibrate/drift following the procedure outlined in the operator's instruction manual.
Determine the instrument blank.
a. Login a minimum of 3 Blank replicates.
b. Press the Analyze button on the instrument screen. After a short delay, the loading head slide-block will open.
c. Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.
d. Clean the upper and lower electrode manually, or, if applicable, remove thecrucible and press the analyze button to clean with the automatic cleaner.
e. Firmly place a graphite crucible on the lower electrode tip.
f. Press the Analyze button on the instrument screen, the lower electrode will close and the analysis sequence will start and endautomatically.
g. Repeat steps 2b through 2f a minimum of three times.
h. Set the blank following the procedure outlined in the operator's instruction manual.
Procedure - Solid Samples:
--Instrument calibration/drift correction.
Place the nickel basket containing the calibration/drift standard into the open port at the top of the loading head.
Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.
Clean the upper and lower electrode manually, or, if applicable, remove the crucible and press the analyze button to clean with the automatic cleaner.
ONH836系列:氧氮氢分析仪(熔融法)
软件特点和优势
Cornerstone氧氮氢分析软件分成4个主要部分:分析、诊断、设定、仪器,界面可以快速导航和组织。工具条、滑动条和下拉式菜单简化了校正和数据处理的参数设定。分析软件同时包括实时的环境参数的监测,提供完整的系统图表模拟。高级诊断程序包括全数字化的在线操作手册、维护模拟演示、图片说明等提供快速指导。Cornerstone氧氮氢分析软件同时支持***的数据文档格式和可变的报告格式。 提供各种无机材料、钢铁、有色金属、硬质合金、陶瓷材料中宽范围的氧氮氢同时分析。元素分析仪
提供各种无机材料、钢铁、有色金属、硬质合金陶瓷材料中宽范围的氧氮氢同时测定。专业分析仪厂家供应
力可ONH836氧氮氢分析仪
特点和优势
国际**的非色散红外及热导检测器 ,无移动部件,不需要手动调整
采用三个**的红外器检测氧含量,同时检测CO和CO2,然后在转化为CO2集中检测,原理上是**完善的,所以不仅可以保证中间量程的测量精度,在**含量和高含量的检测范围内同样可以满足精度要求
高性能的红外检测器配置***恒温绝热技术,消除了外界环境温度的干扰
长寿命的红外发射光源和无漂移的电路设计保证检测器的长期稳定性
力可**的动态流量补偿控制DFC系统,保证了流量系统的完善,可以精确控制整个气路中的流量,保持流量恒定**改善了材料中氮分析的准确度
可以旁路的OMI-2 气路强化过滤装置增强了检测器的稳定性,使得分析结果更加准确
可选自动功能
20位试样自动进样系统
通用下电极坩埚支座,容纳各种坩埚使用
无需人工干预的全自动清扫系统
专业分析仪厂家供应
上海禹重实业有限公司是一家从事仪器科技、医疗科技、检测科技领域内的技术咨询、技术服务,仪器仪表的修理,仪器仪表、实验室设备、机械设备及配件、机电设备及配件、电子产品、化工产品及原料(除危险化学品、监控化学品、烟花爆竹、民用易爆物品、易制毒化学品)、第二类医疗器械的销售,机械设备租赁,电子商务,货物进出口,技术进出口。的公司,是一家集研发、设计、生产和销售为一体的专业化公司。禹重科技深耕行业多年,始终以客户的需求为向导,为客户提供***的光谱仪,色谱仪,质谱仪,样品前处理。禹重科技继续坚定不移地走高质量发展道路,既要实现基本面稳定增长,又要聚焦关键领域,实现转型再突破。禹重科技始终关注仪器仪表行业。满足市场需求,提高产品价值,是我们前行的力量。
SamplePreparationSamplingandsamplepreparationofref
【详情】美国力可LECO氧氮氢分析仪公司介绍:美国力可公司(LECO)始于1936年,以生产用于冶金、机械、...
【详情】Oxygen,Nitrogen,andHydrogeninRefractoryMetalsSumma
【详情】氧氮氢分析仪的优点采用惰气熔融技术,同时测定氧、氮和氢元素含量新设计封闭气路系统,优化气路循环,使氧...
【详情】Oxygen,Nitrogen,andHydrogeninRefractoryMetalsSumma
【详情】Procedure–Powder/ChipSamplesInstrumentcalibration/...
【详情】力可OHN736&836系列仪器采用惰性熔融法,提供各种无机材料、钢铁、有色金属、硬质合金陶瓷材料中...
【详情】SamplePreparationTypically,titaniumandzirconiumsam
【详情】ONH836系列:氧氮氢分析仪(熔融法)软件特点和优势Cornerstone氧氮氢分析软件分成4个主...
【详情】Procedure-SolidSamplesInstrumentcalibration/driftc
【详情】