分析仪基本参数
  • 品牌
  • LECO
  • 型号
  • 齐全
分析仪企业商机

Sample Preparation

Typically, titanium and zirconium samples are chemically etched to remove surface contamination when oxygen and nitrogen are determined. However, etching can introduce hydrogen into the sample.

ASTM method E 1409 "Determination of Oxygen and Nitrogen in Titanium and Titanium Alloys by the Inert

Gas Fusion Technique", as updated in 1996, permits either etching or abrading (filing) of the test specimen.

ASTM E 1447 "Determination of Hydrogen in Titanium and Titanium Alloys by the Inert Gas Fusion Thermal

Conductivity/Infrared Detection Method" permits surface preparation by abrading (if necessary to remove

contamination). Differences in sample preparation present somewhat of a dilemma regarding simultaneous

determination of O, N, and H in titanium. However, abrading samples with a file to remove surface

contamination will yield accurate O, N, and H results. The ONH836 utilizes a high-power electrode furnace to quickly and efficiently release the target gases from within the sample, which allows for a very rapid simultaneous determination of oxygen, nitrogen, and hydrogen.

力可***仪器采用触摸屏技术和在线软件平台,增强了仪器的可操作性、降低了分析成本、节省实验室桌面空间。山西LECO分析仪多少钱

山西LECO分析仪多少钱,分析仪

氧氮氢分析仪的常见故障及解决方法

供电正常、通讯正常,点击确认键后分析仪不工作。这是没有水流,炉子温度太高或仪器通道电压不正常。如没有水流,炉子温度太高这些信息会显示在显示器画面上,但没有信息显示说明这两项正常。接下来检查仪器通道零位电压,如果比±3V高出1V以上,可能是因为气瓶空了,或者是空气进入到分析仪中。检查并更换化学试剂,如果有空气进入热导池里,热导池的电压就会<-6V,此时打开右面的门,堵住炉子气体进口,10s后,热导池电压值必然升高。经过逐一排查,**终确认碱石棉有问题,更换后仪器正常。 进口分析仪厂家报价通用下电极坩埚支座,容纳各种坩埚使用。

山西LECO分析仪多少钱,分析仪

Procedure – Powder/Chip Samples

Determine the instrument blank.

Press the Analyze button on the instrument screen again, the loading head slide-block will close and the lower electrode will open.

Clean the upper and lower electrode either manually or remove the crucible and press the analyze button to clean with an automatic cleaner if applicable.

Add approximately 0.05 g of *** Graphite Powder to a 782-720 Graphite Crucible.

Firmly place the crucible on the lower electrode tip or appropriate autoloader position.


Procedure – Powder/Chip Samples

Instrument calibration/drift correction.

Calibrate/drift following the procedure outlined in the operator's instruction manual.


Analyze Samples.

Login Sample with the appropriate number of reps.

Weigh approximately *** grams of appropriately prepared sample into a *** Nickel Capsule, enter mass and sample identification into appropriate rep fields. If applicable, place the nickel capsule in the

appropriate autoloader position.

Repeat steps 3c through 3i for sample analysis.


ONH836仪器通过***采纳客户的反馈意见和创新设计。

山西LECO分析仪多少钱,分析仪

Instrument Highlights and Features


Features and Benefits

LED light ring illuminates the furnace area

Choice of either argon or helium carrier gas

Novel electrode design increases heat transfer efficiency for increased stability

Non-touch interface systems are also available

User-friendly brand software



High-Performance Detector Design

Thermostatic construction provides increased protection from ambient temperature fluctuations

Optimized emitter control and detection circuitryimproves the IR cell lifetime and long-term stability,

resulting in superior accuracy and precision

Infrared detection for the determination of oxygen, thermoconductivity detection for the determination

of nitrogen




***红外池的恒温绝热技术消除了外界环境温度的干扰。安徽进口分析仪采购

用户友好界面的Cornerstone™ 软件。山西LECO分析仪多少钱

Sample Preparation


Sampling and sample preparation is an important issue because traditional methods used to obtain samples for oxygen and nitrogen determination are different from those recommended for hydrogen, especially when sampling molten metal. The main difference in steel sampling procedures for oxygen/nitrogen and hydrogen is due to the mobilityof hydrogen. Special precautions must be used when sampling for hydrogen. From molten steel and iron, a sample must be quickly quenched in cold water and chilled in a refrigerant such as liquefied nitrogen or a mixture of acetone and solid carbon dioxide in order to reduce losses of hydrogen from diffusion. Losses of oxygen and nitrogen from diffusion are not a problem. A sample that is taken for hydrogen and

chilled in a refrigerant can also be used for oxygen and nitrogen determination. However, a sample that is typically taken for oxygen and/or nitrogen determination is not suitable for hydrogen determination due to hydrogen loss (diffusion). Surface contamination must be removed by filing or light grinding, using care not to overheat the sample.


山西LECO分析仪多少钱

与分析仪相关的文章
与分析仪相关的问题
与分析仪相关的搜索
与分析仪相关的扩展资料【更多】
变频功率分析仪是用于各类变频调速系统的电压、电流、功率、谐波等电量测试、计量的新型测量设备,是变频技术高速发展的必然产物,也是 变频技术持续健康发展的重要基础仪器,更是变频设备能效评测不可或缺的工具。